How are Insulating Oil Dielectric Loss Tester and resistivity measured?

Engineers specializing in oil testing know that once transformer oil ages or becomes contaminated with polar impurities, its dielectric loss factor (tanδ) skyrockets while its volume resistivity plummets. If either of these parameters fails to meet standards, the oil must be filtered or replaced; otherwise, the transformer will overheat or even break down.
However, measuring these two parameters on-site is a nightmare for lab technicians: the oil temperature must be perfectly stable at 90℃±0.5℃; any temperature fluctuation renders the data unusable. Cleaning the oil cup is extremely inefficient; even a drop of solvent or a single fiber can double the tanδ. Our Insulating Oil Dielectric Loss Tester is specifically designed to solve these "mysterious" problems. Using advanced high-frequency induction heating, precision three-electrode machining, and heterogeneous frequency anti-interference technology, it accurately and stably measures the dielectric loss and resistivity of insulating oil.
What advantages does this Insulating Oil Dielectric Loss Tester offer to customers?

Inter-frequency interference suppression technology: Power frequency interference is extremely high in substations. We employ 45Hz/55Hz inter-frequency testing technology (or frequency conversion technology) to completely filter out 50Hz power frequency interference through digital filtering, accurately extracting even the smallest leakage currents in the pA (picoampere) range under strong electric fields.
Simultaneous measurement of dielectric loss and resistivity: High-voltage AC is applied to measure dielectric loss (tanδ) and capacitance, while high-voltage DC is applied to measure volume resistivity (ρ). A single temperature rise yields results for both parameters simultaneously, eliminating the need for cable or instrument replacement.
Fully automatic cleaning and oil draining (multi-cup version): After testing, the instrument automatically opens the oil drain valve, automatically pumping in petroleum ether/anhydrous ethanol to clean the electrodes, followed by hot air drying. This cleaning is more thorough and effective than manual cleaning, preventing contamination of the next oil sample by the previous high-loss sample.
What precautions should be taken when using Insulating Oil Dielectric Loss Tester?
1. When washing the oil cup, never use lint-shedding paper towels or cotton yarn! Cleaning the oil cup must be done with aviation gasoline or analytical grade petroleum ether + anhydrous ethanol. Wipe the electrodes only with dedicated lint-free paper or a clean silk cloth. Using ordinary paper towels will leave tiny fibers that act as conductive bridges under high voltage, directly causing an overestimation of tanδ and an underestimation of resistivity.
2. When pouring the oil sample, avoid air bubbles! Pour the oil slowly along the glass rod or the wall of the oil cup. Tiny air bubbles between the electrodes have extremely low dielectric constants, leading to an underestimation of capacitance and severe distortion of tanδ.
3. Temperature must be truly stable! After the instrument indicates that 90℃ has been reached, do not test immediately. Let the oil sample stand at 90℃ for 5-10 minutes to ensure that the internal temperature of the oil sample is completely consistent with the electrode temperature; otherwise, thermal convection will cause erratic data readings.
4. Be aware of the polarization effect! When measuring resistivity, a high DC voltage is applied. Prolonged pressurization can cause impurity ions in the oil to "polarize" and accumulate on the electrode surface, resulting in a continuous increase in the resistivity reading over time. Therefore, the data must be read strictly according to the standard-specified pressurization time (e.g., 60 seconds), and cannot be based on subjective judgment.
How can I maintain the product to extend its lifespan?
Oil cup oxidation and impact protection: Scratches or oxidation on the electrode surface of the oil cup will distort the electric field. During disassembly and cleaning, avoid impacts from hard objects. When not in use for extended periods, clean and dry the oil cup before storing it in a dedicated desiccator.
Oil drain line cleaning: Long-term residue of high-viscosity, aged oil in the automatic oil drain line can easily cause blockages. It is recommended to perform a "deep cleaning" procedure with hot petroleum ether once a month.
What parameters are used to determine the value of medium loss?

Power supply voltage: AC 220V±10%
Power supply frequency: 50Hz/60Hz±1%
Measurement range: Capacitance 5pF~200pF; Relative permittivity 1.000~30.000; Dielectric loss factor 0.00001~100
DC resistivity 2.5 MΩm~20 TΩm
Measurement accuracy: Capacitance ±(1% reading + 0.5pF)
Relative permittivity ±1% reading
Dielectric loss factor ±(1% reading + 0.0001)
DC resistivity ±10% reading
Warranty Policy: 24-month warranty on the entire machine (excluding damage caused by human error and consumables).
Lifetime Maintenance: Lifetime paid repair service provided after the warranty period, charging only the cost of materials.
Rapid Response: 24/7 technical support hotline, fault response time < 2 hours.