Transformer Capacity

Transformer Capacity
Details:
Products Description Introduction Transformer capacity t ester is specialized in bad power users evading basic electricity fee and secretly adding capacity problems and is a new-type high precision instrument specially used for the measurement of the transformer capacity and characteristic...
Send Inquiry
Description
Send Inquiry

Products Description

20250716153524

Introduction

Transformer capacity tester is specialized in bad power users evading basic electricity fee and secretly adding capacity problems and is a new-type high precision instrument specially used for the measurement of the transformer capacity and characteristic parameters. This product use wide-screen color LCD , English display, simple and quick menu operation, human-machine interface is very friendly. There is a built -in rechargeable battery inside the instrument and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets of transformer. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the voltage regulator, current regulator and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of your work.

This is a multi-functional measuring instrument, which is equivalent to two common meters: such as active transformer capacity tester plus transformer parameter tester. It can be used for test transformer capacity, type, no-load current, no-load loss, load loss, impedance voltage and so on.

This product has many advantages such as small dimension, light , high accuracy, good stability, simple operation and so on. It can replace of the commonly many meters, you can measure the transformer loss and capacity with simple wiring and convenient testing in only one this kind of instrument so that the work efficiency can be greatly improved.

 

Function

 

We can measure a variety of distribution transformer, power transformer capacity instead of the additional extra power. It is more convenient and efficient.

Combined with the external power source, voltage, current regulator equipment etc, it can measures various transformer parameter such as no-load current, no-load loss, impedance voltage, load loss and so on.

Characteristic test of transformer, test range is wide,flexible configured.only through the simple connection to current transformer and voltage transformer, test scope can be enlarged to high-grade power transformer.

Short-circuit the terminals of cable,humanization design,with lock,easy connected to fasten units of transformation.

All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients etc), then the instrument can automatically calibrate such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction,so that the accurate is much higher

The maximum voltage is up to 750V and the maximum current is up to 100A range with protection circuit in it,when you make the characteristic test of transformer.don't worry the precision and damage of the instrument due to in-proper shift.

The voltage and current range can be very flexible and easy to expand by connecting the external CT or VT

It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature tolerance, brightness adjustable type LCD screen, which can adapt to the different temperature.

Thermal sensitive printer is set inside the instrument,it can easily print on site.

20250716153524

Technical Parameters

 

20250716153520

1. The output range of built-in battery

Voltage:0~10V

Current:0~10A

2. The input range of characteristic test power source

Voltage:0~750V

Current:0~100A

3. Accurate of test

Voltage, current:±0.2%

Power:±0.5%(CosΦ>0.1), ±1.0%(0.02

4. Working temperature

-20℃~+60℃

5. The requirement of charger

Electric supply AC160V~265V

Adapter output 12.6V 1000mA

6. Insulation

⑴ Insulation resistance between capacity , voltage, current to enclosure ≥100MΩ

⑵ bear the 2kV power frequency (effective value) between the

input power and machine enclosure, testing time is 1 minute.

7. Volume

32cm×25cm×12cm

8. Weight

2.5KGS

Usage instructions

Start Running
Click "Start" -> "Program" -> "Test Instrument Data Management System 2.0" -> "Test Instrument Data Management System 2.0" to start running this software.
Software Login
Since the data stored in this software is the main information, after running this software, you need to input the username and password to log in to the software first. Unauthorized personnel are not allowed to operate this software without permission.

After logging into the system, enter the main interface of this system. Click "System Settings" -> "Password Settings" to open the "Password Settings" interface.
If you need to add a new operator, simply enter the username of the new operator in the "Operator" column and input the new password twice that you want to register. After confirming there are no errors, click the "Add" button. The addition will be successful.
When you need to delete an operator, you can select the operator to be deleted in the "Operator" column. After selection, click the "Delete" button, and the operator can be deleted.
Note: The operations of adding and deleting operators can only be performed by the "System Administrator" and other operators cannot perform these operations.

f you need to change the password, click the "Password Modification" tab to enter the password modification window. Select the username for which you want to change the password, and then enter the original password and the new password one by one. The new password needs to be entered twice, and then click the "OK" button. Data upload
When conducting tests on the transformer at the experimental site using the tester and saving the data, you can upload the saved data to this software for data management operations. This is also the core function of this software.Before data upload, connect the computer and the tester using a data cable. Please use the dedicated data cable configured for you. After the data cable is connected, click the main menu "System Configuration" -> "Serial Port Settings". Open the "Serial Port Settings" window. Select the correct serial port.

20250716153524

 

 

 

 

 

 

Hot Tags: Transformer Capacity, China Transformer Capacity manufacturers, suppliers, factory, 3102Transformer DC Resistance Tester, Electricity Transformer DC resistance tester, Power transformer on load tap changer tester, Power transformer short circuit impedance tester, Transformer Winding DC Resistance Test Equipment, Winding DC resistance measuring deviceinstrument

Send Inquiry