Product Overview Power Transformer Tester On-load tap changer is the only moving part connected with the transformer circuit, so the detection of on-load tap changer should be attracted more and more attention. In << Electric power equipment handover and preventive test procedures >>...
Send Inquiry
Description
Send Inquiry

Dual Canopy Mechanic Electrical Engineering Co., Ltd. is one of the leading manufacturers and suppliers of On-load tap changer test in China. Please feel free to wholesale discount products for sale here and get quotation from our factory. Customized orders are welcome.

 

What is On-load tap changer test?

 

DSC0505

The On-Load Tap Changer Test System is used for comprehensive testing of the dynamic resistance (DRM), switching transition time, motor drive current, and mechanical characteristics of on-load tap changers (OLTCs) of transformers. It supports waveform acquisition, trend comparison, and automatic report output, and is suitable for factory testing, acceptance testing, condition-based maintenance, and troubleshooting.

 

What is Technical Indicators?

 

Output current 1.0A,0.5A,0.2A

Transition resistance range:

      0.3Ω~20Ω(1.0A)

      5Ω~40Ω(0.5A)

      20Ω~100Ω(0.2A)

Transition time :0~320ms

Open circuit voltage: 24V

Transition resistance accuracy:±(5%±0.1Ω)

Transition time :±(0.1%±0.2ms)

Resonant frequency:20kHz

DSC0477

What services do we provide?

 

Selection and Matching: Recommended configuration based on OLTC type (resistive/reactive), transformer capacity, test items (DRM/motor current/timing), and site conditions.

Connection Scheme Confirmation: Assist in verifying terminal numbers, motor current connection points, auxiliary contact definitions, and sensor installation locations.

Baseline Establishment Recommendations: Provide initial test data recording specifications and range management templates for easy subsequent trend management.

Document Support: Technical parameter tables, typical wiring diagrams, tender documents, and typical application cases (to the extent available).

20250613152229
 

FAQ

 

 

Q1: What are the main items tested in the On-Load Tap Changer Test?

A: The main items include Dynamic Resistance (DRM), switching transition time, motor drive current waveform, and auxiliary contact timing, etc. Specific testing depends on the model configuration.

 

Q2: What is the fundamental difference between DRM and DC resistance testing?

A: DC resistance measures static values; DRM collects resistance changes in real time during OLTC operation, reflecting the dynamic contact state during switching. The two are complementary, not substitutes.

 

Q3: Why is DRM better at detecting potential OLTC problems than traditional testing methods?

A: Traditional methods measure in a static state and cannot detect instantaneous contact problems during switching; DRM collects data during actual switching, more closely resembling real-world operating conditions.