Dual Canopy Mechanic Electrical Engineering Co., Ltd. is one of the leading manufacturers and suppliers of Acid Value Tester in China. Please feel free to wholesale discount products for sale here and get quotation from our factory. Customized orders are welcome.
Is the manual Acid Value Tester still usable?

Those who perform oil testing know that measuring the acid value (the number of milligrams of KOH required to neutralize 1 gram of oil sample) of insulating oil and turbine oil is crucial for monitoring the oil's aging process and the corrosiveness of acidic substances.
Previously, manual titration (GB/T 264) was used. The lab technician had to constantly monitor the color change in the conical flask; a slight lapse in attention could result in overdosing and invalidating the data. Furthermore, the extractant (isopropanol, etc.) had a strong odor, and long-term inhalation was harmful to health. Our Acid Value Tester automates the entire process: adding liquid, extraction, titration, endpoint determination, and cleaning. Simply put, it uses high-precision photoelectric sensors and a micro-pump to replace human eyes and hands, accurately and quickly measuring trace acid values while protecting the health of the lab technician.
What does a product selection guide include?
1. Fully Automatic Trace Acid Value Analyzer (Colorimetric/Extraction Method)
(The absolute mainstay for power system insulating oils/turbine oils, highly recommended)
Based on GB/T 264 and GB/T 7599 standards. Employs photoelectric colorimetry to determine the titration endpoint. Specifically designed for light-colored, transparent operating oils with extremely low acid values (<0.1 mgKOH/g). Standard equipment for power plants and power supply bureau oil maintenance teams.
2. Fully Automatic Potentiometric Titration Acid Value Analyzer (Potential Method)
(Preferred for petrochemical, fire-resistant oils, and dark-colored oils)
Based on GB/T 7304 / ASTM D664 standards. Employs a pH glass electrode to determine potential jumps. Independent of color changes, suitable for measuring dark-colored aged oils, phosphate ester fire-resistant oils, and high-acid-value crude oils and lubricating oils in the petrochemical industry.

Can the parameters used meet the testing standards?

Technical indicators
Test range: 0.002~1mg KOH/g
Measurement error: ≤±0.005mg KOH/g
Repeatability: ≤0.005mg KOH/g
Applicable temperature: 10℃~45℃
Applicable humidity: ≤85%RH
Power supply: AC220V/50Hz
Power: 50W
Power supply voltage: AC 220V ± 20% 50Hz ± 10%
Acid value measurement range: 0.0001 - 5.0000 mgKOH/g
Minimum resolution: 0.0001 mgKOH/g
Measurement accuracy: The acid value is between 0.001 - 0.1000 mgKOH/g,
Allowable error range: 0.02 mgKOH/g
What process was used to create an acid value tester?
Precision machining of sample cups: The transmittance and inner diameter of the oil cup in colorimetric methods directly affect photoelectric judgment. Our quartz/borosilicate glass oil cups are precision ground using CNC machine tools, ensuring extremely high batch consistency and preventing optical path deflection.
Liquid system airtightness pressure testing: After assembly, each liquid system must be placed on an airtightness testing bench and pressurized for 24 hours to ensure zero microbubbles and zero leakage rate.
Calibration equipment: High-precision microbalance (1/100,000), standard acid value reagent (e.g., potassium hydrogen phthalate), standard pH buffer solution.
Environmental testing: High and low temperature alternating chamber (to test the effect of reagent viscosity changes at different room temperatures on pump accuracy).

What special precautions should be taken when using this equipment?
1. Reagents must be fresh and sealed! Extraction solutions (isopropanol/toluene) readily absorb moisture and CO2 from the air, and neutralization solutions (KOH) readily react with glass. Reagent bottles must be strictly sealed; once opened, their shelf life is typically no more than 1-2 months. If an abnormally high blank value is detected, replace the reagent immediately!
2. Air purging in tubing is fundamental! After each reagent change or after a long period of inactivity, a tubing purging/cleaning procedure must be performed. Even a single air bubble the size of a grain of rice in the tubing will result in inaccurate volume output by the micro-pump, causing the titration endpoint to occur earlier or later than intended.
3. Oil sample weighing must be precise! Especially when measuring trace acid values, the oil sample volume is typically 8g-10g. It must be accurately weighed using a 0.01g or 0.1g balance, and the actual weight must be entered into the instrument. A difference of 0.1g will deviate from the intended result.
4. Be aware of environmental CO2 interference! Do not breathe heavily in front of the instruments in the laboratory, and do not conduct experiments that produce acidic/alkaline gases next to the instruments.
How to maintain it to extend its lifespan?
1. Thorough cleaning is essential after use! After each day's testing, be sure to perform the instrument's "deep cleaning" procedure, rinsing the tubing, titration needle, and oil cup with anhydrous ethanol. If the instrument will be shut down for more than 3 days, it is recommended to fill the tubing with anhydrous ethanol to prevent crystallization.
2. Regularly calibrate the micro-pump: Every six months, weigh the pure water dispensed by the instrument using a 0.01% balance, convert the weight to volume, and calibrate the micro-pump's step coefficient to ensure accurate dispensing.
3. Electrode maintenance (for potentiometric titration): If using a potentiometric titrator, the pH electrode must be immersed in a 3mol/L KCl solution when not in use; never leave it dry.
After-sales Service
Warranty Policy: 24-month warranty on the entire machine (excluding damage caused by human error and consumables).
Lifetime Maintenance: Lifetime paid repair service provided after the warranty period, charging only the cost of materials.
Rapid Response: 24/7 technical support hotline, fault response time < 2 hours.

FAQ
1. Q: Why is the measured acid value negative or close to zero?
A: This is most likely due to an improperly performed blank test, or the extract absorbing too much CO2, resulting in a blank value higher than the amount of sample consumed. Recommendations: 1. Prepare fresh extract and neutralization solutions; 2. Check for leaks in the tubing; 3. Confirm that the oil sample is truly extremely pure (new oil).
2. Q: My oil sample is very dark (e.g., old transformer oil that has been running for over ten years). Can I still use colorimetry?
A: Not recommended. Colorimetry relies on light penetrating the oil sample. Dark oil can obstruct the photoelectric sensor, leading to misjudgment of the endpoint. For dark-colored or severely aged oils, we strongly recommend purchasing our "Fully Automatic Potential Titration Acid Value Analyzer (Potential Method)," which measures potential jumps using electrodes and is unaffected by color.
3. Q: What should I do if the instrument displays "Titration Timeout" or "Endpoint Not Found"?
A: There are three possible reasons: 1. The concentration of the neutralizing solution (KOH) was incorrectly calibrated or is ineffective; 2. The acid value of the oil sample is extremely high, exceeding the range of a single titration (it is recommended to reduce the sample size); 3. The stirring speed is too slow, and the oil and water are not fully emulsified and extracted.
Hot Tags: Acid Value Tester, China Acid Value Tester manufacturers, suppliers, factory