Partial Discharge Accessories Partial Discharge Equipment

Partial Discharge Accessories Partial Discharge Equipment
Details:
Ultrasonic sensors (US) are used to receive ultrasonic signals generated by partial discharge.
Send Inquiry
Description
Send Inquiry

SGCS-II/IIA Ultrasonic Sensors

 

Introduction

 

Ultrasonic sensors (US) are used to receive ultrasonic signals generated by partial discharge. SGCS-II is used for live inspection and fault location of partial discharge of oil-immersed high-voltage electrical equipment. SGCS-IIA is used to receive ultrasonic signals generated by partial discharge of GIS.

product-289-171

 

Product Paramenters

 

Frequency Band

20 kHz-300kHz

Mean sensitivity

>50dB

Center Frequency

II40kHz/IIA 80kHz

Output Interface

Standard BNC

Gain

40dB±1dB

Power Supply

12V/40mA DC

Dynamic Range

>80dB

Operating Temperature

-10℃~40℃

Peak Sensitivity

>70dB

Storage Temperature

-20℃~50℃

 

SGCS-IV Non-Contact Ultrasonic Sensor

 

Introduction

 

The non-contact ultrasonic sensor (NCU) detects the ultrasonic waves propagating in the air when partial discharge occurs. It requires a good air transmission path between the discharge source and the sensor. It cannot detect switch cabinets that are well sealed and have no pores or air gaps.

product-221-34

 

Product Paramenters

 

Center Frequency

40kHz

Output Interface

Standard BNC

Resolution

0.1μV

Power Supply

12V/40mA DC

Accuracy

±0.1μV

Operating Temperature

-10℃~40℃

Measuring Range

0.5μV~1mV

Storage Temperature

-20℃~50℃

 

SGCS-II High-Frequency Current Transformer

 

Introduction

 

The high-frequency current transformer (HFCT) is clamped onto the grounding wire of high-voltage electrical equipment to detect the pulse current signals generated by partial discharge, thereby obtaining the partial discharge information of the equipment being tested. It is mainly used for partial discharge signal detection in medium and high-voltage equipment such as cables, transformers, reactors, GIS, and switchgear.

product-183-156

 

Product Paramenters

 

Frequency Band

1M-30MHz

Resolution

1dB

Transfer Resistance

>5mV/mA(10MHz )

Output Interface

Standard BNC

Output Impedance

50Ω

Power Supply

Passive

Detection Sensitivity

-20dB

Operating Temperature

-10℃~40℃

Measuring Range

-20~80dB

Storage Temperature

-20℃~50℃

Measurement Error

±1dB

   

 

SGCS-IV UHF Sensor

 

Introduction

 

The use of UHF technology to detect partial discharge has become the development direction of GIS partial discharge detection technology. The UHF ultra-high frequency sensor meets the detection requirements of wide bandwidth, low noise, high sensitivity and large dynamic range, and improves the performance of the UHF partial discharge detection system.

product-199-140

 

Product Paramenters

 

Frequency Band

300MHz~1.5GHz

Equivalent Height

>10mm

Output Interface

N-type

Working Environment Temperature

-40℃~80℃

Detection Sensitivity

10pC

Working Relative Humidity

5%~95%, no condensation

Protection Level

IP65

Measuring Range

10pC~10000pC

 

SGCS-II TEV Sensor

 

Introduction

 

The TEV sensor can sense the transient voltage signal on the metal cabinet of the switch cabinet. When using, place the TEV sensor close to the metal cabinet.

product-132-136

 

Product Paramenters

 

Output Interface

Standard BNC

Detection Bandwidth

3MHz-100MHz

Power Supply

Passive

Measuring Range

0~60dB

Operating Temperature

-10℃~40℃

Measurement Error

±1dB

Storage Temperature

-20℃~50℃

Resolution

1dB

 

SGCS-2001 Ultrasonic Wave Concentrator

 

Introduction

 

It can double the detection distance and can accurately locate ultrasonic signals scattered at a long distance and increase its sensitivity. It is suitable for detecting gas leaks, electrical discharges, leakage traces and arcs in situations where users cannot approach the equipment.

product-202-160

 

Product Paramenters

 

Measurement Gain

16dB

Weight

0.6kg

Center Frequency

40kHz

Operating Temperature

-10℃~40℃

Parabolic Reflector Outer Diameter

140mm

Storage Temperature

-20℃~50℃

Parabolic Reflector Standard Diameter

132mm

   

 

product-800-600
product-800-600
product-800-600
product-800-600
product-800-600

Hot Tags: partial discharge accessories partial discharge equipment, China partial discharge accessories partial discharge equipment manufacturers, suppliers, factory, Partial Discharge Comprehensive Analyzer, Partial discharge fault mobile inspection equipment, Partial discharge special sensor accessories, Ultrasonic insulation inspection inspection instrument, Ultrasonic partial discharge inspection instrument, Ultrasonic partial inspection instrument