What is Transformer Winding Deformation Analysis?

 

1

Transformer Winding Deformation Analysis (SFRA) testing employs specialized instrumentation to evaluate both mechanical and electrical integrity within power transformers, reactors, and inductive equipment. This approach diverges from conventional insulation testing by examining how transformer windings behave across varying frequencies rather than capturing simple resistance or capacitance figures.

The methodology rests on treating transformer windings as sophisticated RLC networks. These conductive assemblies generate distinct frequency response profiles-plotting amplitude and phase against frequency-that establish baseline fingerprints for individual units. Internal physical disturbances, whether induced by short-circuit mechanical stresses causing winding displacement, core realignment, or degraded clamping pressure, inevitably reshape the inherent inductance and capacitance properties. Such alterations register as measurable shifts in the frequency response signature.

The test procedure involves sweeping a low-voltage sinusoidal signal through an extended frequency spectrum, commonly spanning 20 Hz to 2 MHz or beyond, while capturing the resulting output characteristics. This technique achieves exceptional sensitivity in revealing subtle geometric changes inside the transformer enclosure. Maintenance teams rely on SFRA to uncover winding deformation, core-related anomalies, and open or short-circuit conditions-all without the expense and operational impact of dismantling the apparatus.

What are the technical characteristics?

 

Characteristics of transformer windings are measured with frequency sweep method. Deformations of windings such as distortion, swell or displacement of 66kV and above transformer are measured by detecting amplitude-frequency response characteristics of each winding, not requiring lifting of transformer enclosure or disintegration.

Quick measuring, measuring of a single winding is within 2 minutes.

High frequency accuracy, higher than 0.001%.

Digital frequency synthesis, with higher frequency stability.

5000V voltage isolation fully protects safety of the testing computer.

Able to load 9 curves at the same time and automatically calculate parameters of each curve and diagnose winding deformations to provide the reference diagnosis conclusion.

Analysis software has powerful functions and software and hardware indicators satisfy national standard DL/T911-2016/IEC60076-18.

Software management is humanized with high degree of intelligence. You only need to click one key to complete all measurements after setting of parameters.

The software interface is concise and vivid, with clear menus of analysis, save, report export, print, etc.

5

 

What are the highlights of the technical features?

1. Broadband Scanning and High Resolution
Frequency Range: The standard test range typically spans from 20 Hz to 2 MHz, while certain high-end models can extend up to 20 MHz.
Low-Frequency Band (20 Hz – 2 kHz): Primarily reflects the characteristics of the iron core magnetic circuit and mutual inductance.
Mid-Frequency Band (2 kHz – 20 kHz): Reflects the overall inductance characteristics of the windings.
High-Frequency Band (20 kHz – 2 MHz): Reflects the distributed capacitance of the windings and subtle details of their geometric structure; it is extremely sensitive to localized deformations.
Scanning Precision: Employs either logarithmic or linear scanning modes with high frequency resolution, ensuring the capture of resonance point shifts within narrow frequency bands.
2. "Fingerprint" Comparison and Analysis Technology
Three-Phase Comparison: The winding structures of the three phases within a single transformer are symmetrical; theoretically, their frequency response curves should exhibit a high degree of overlap. By comparing the discrepancies among the A, B, and C phase curves, the specific faulty phase can be quickly identified.
Historical Comparison: Field-measured curves are superimposed onto factory test data or historical records; even minute shifts in the curves serve as indicators of changes within the internal structure.
Phase Analysis: In addition to amplitude-frequency characteristics, phase-frequency characteristics are often more sensitive to specific types of faults (e.g., capacitive faults).
3. Precision Measurement and Interference Immunity
Dynamic Range: Features a wide dynamic range (e.g., >100 dB), enabling the simultaneous and precise measurement of both low-impedance (short-circuit) and high-impedance (open-circuit) conditions.
Interference-Resistant Design: Utilizes correlation filtering techniques to accurately extract faint response signals, even within substation environments characterized by strong electromagnetic interference.
Impedance Measurement: Directly measures and displays impedance magnitude and phase angle, rather than merely providing voltage ratio data.
4. Portability and Field Adaptability
Lightweight Design: The main unit typically weighs only 3–5 kg, making it easy to transport to field sites.
Rapid Connection: Employs specialized test clips to simplify the on-site wiring and connection process.

 

How are professional services delivered?

Model Selection Consultation: Based on the client's transformer capacity, voltage class, and diagnostic requirements (e.g., the need for ultra-high-frequency band analysis), we recommend the appropriate frequency range and accuracy class.
Standard Interpretation: We address application-related inquiries regarding SFRA testing standards, such as IEEE C57.149 and DL/T 911.
Case Studies: We share typical case studies involving winding deformation and core faults, along with their corresponding frequency response curve characteristics, to help users understand the underlying diagnostic principles.
Software Demonstration: We demonstrate the features of the analysis software, such as curve comparison and automated diagnostic report generation.

modular-1
 

 

 

FAQ

 

Q1: Do test results suffer significant influence from test leads? How can this influence be eliminated?
A: The influence is indeed significant, particularly in the high-frequency range (>100 kHz). The inductance and capacitance of the test leads can form additional resonant circuits in conjunction with the winding under test.

Elimination Methods:
Use the standard test leads provided by the manufacturer, ensuring consistency in both length and physical arrangement.
When performing comparative analysis, ensure that the lead arrangement remains absolutely identical between consecutive tests.
Focus on the relative changes in the curves (e.g., three-phase comparisons or historical comparisons) rather than on absolute numerical values, as the influence of test leads is typically systemic in nature.


Q2: How long does an SFRA test take?
A: Compared to withstand voltage tests or insulation resistance measurements, SFRA testing takes a relatively longer time. A complete three-phase test (including wiring, scanning, and data saving) typically requires 20 to 40 minutes, depending on the number of scan points and the selected frequency range. However, considering the wealth of diagnostic information it provides, this is a highly efficient process within the context of transformer maintenance.

 

Q3: Why are the measured curves sometimes irregular-featuring numerous spikes or "glitches"-rather than being smooth?
A: This is typically caused by ambient electromagnetic interference or poor grounding. In substation environments, strong electromagnetic fields can couple into the measurement circuit.

Solutions: Verify that the grounding for both the test instrument and the equipment under test is secure and reliable; use test leads with superior shielding capabilities; enable the averaging filter function within the software; and, if necessary, wait for local sources of interference (such as large motors currently in operation) to be shut down before proceeding with the test.

 