Dual Canopy Mechanic Electrical Engineering Co., Ltd. is one of the leading manufacturers and suppliers of HV AC Divider in China. Please feel free to wholesale discount products for sale here and get quotation from our factory. Customized orders are welcome.
How does a HV AC Divider become a monitoring device for high-voltage measurement tests?

In high-voltage test setups-whether for AC withstand, partial discharge, or impulse testing-the booster set supplies the voltage, but the divider is what actually measures the stress reaching the test object. That distinction matters because the divider closes the measurement loop. If it is wrong, the applied stress is wrong, regardless of what the source controller displays.
Divider errors show up in several ways. Ratio inaccuracy is the most visible, but temperature drift during extended test sequences and partial discharge generated within the divider structure are harder to detect and equally problematic. Under-testing is the quieter failure: the reading says you reached the specified level, but the actual voltage was lower, allowing latent defects in transformer insulation, GIS spacers, or cable layers to pass undetected. Over-testing is more immediate-applying even a few percent above the rated stress can push solid insulation past its design margin and damage the test object irreversibly.
For high-voltage laboratories, transformer manufacturers, cable factories, and research institutes, divider selection involves more than verifying the ratio. The temperature coefficient determines whether readings stay consistent from morning to afternoon. Partial discharge inception levels must be high enough that the divider does not introduce noise that masks the very signals you are trying to detect from the test object. And the physical layout must resist flashover under the humidity, dust, or proximity conditions typical of industrial test floors.
What parameters are used to define the value of high voltage?
|
Measuring range (kV) |
AC 50kV |
AC 100kV |
AC 150kV |
AC 200kV |
AC 300kV |
|
|
DC 50kV |
DC 100kV |
DC 150kV |
DC 200kV |
DC 300kV |
|
Accuracy |
AC: 1.0 level DC: 0.5 level |
||||
|
Voltage divider impedance |
240MΩ |
400MΩ |
600MΩ |
800MΩ |
1200MΩ |
|
Voltage Divider Capacitance Ratio |
250pF |
250pF |
150pF |
250pF |
75pF |
|
Pressure ratio |
3000∶1 |
5000∶1 |
7500:1 |
10000∶1 |
15000∶1 |
|
Usage Environment |
Temperature range: 0~40℃ Relative humidity ≤85% |
||||
How to accurately select and match items?
1. AC/DC High Voltage Divider
(Mainstay for High Voltage Testing/Withstand Voltage Tests) Features a parallel resistor-capacitor (RC) or pure resistor/capacitor structure. Primarily used for measuring power frequency AC and DC high voltages. Suitable for routine AC withstand voltage and DC leakage tests on transformers, cables, and switchgear.
2. Impulse Voltage Divider
(Impulse Testing/The Pinnacle of Scientific Research, Highest Technical Content)
Designed specifically for measuring lightning impulses (1.2/50μs) and switching impulses (250/2500μs). Requires extremely high square wave response speed (nanosecond level), accurate wavefront timing, and undistorted waveform.
3. PD-Free Precision Divider
(Standard Equipment in Partial Discharge Testing Laboratories)
Utilizes special internal shielding and voltage equalization design, resulting in extremely low partial discharge (typically <3pC or <5pC). Specifically designed for use with partial discharge instruments, ensuring that no background interference is introduced into the partial discharge test of the test sample.
Which workshops and tools are used to manufacture HV AC Divider?
Cleanroom for Partial Discharge: Assembly and oiling/grouting of the device body must be carried out in a Class 100,000 cleanroom. Even a single dust particle or air bubble in the air can be a lethal source of partial discharge under high voltage.
Vacuum Treatment Equipment: Equipped with large vacuum drying tanks and vacuum oiling machines to ensure that the insulating medium is absolutely free of air bubbles and moisture.
What are some safe practices for using it?
1. Grounding! Single-point grounding! The bottom grounding terminal of the voltage divider must be directly and reliably connected to the dedicated grounding network in the high-voltage hall using thick copper braided wire. Series grounding is strictly prohibited, as is connecting it to rusted channel steel. Poor grounding will cause the low-voltage arm potential to float, directly burning out the measuring instruments at the rear!
2. Safety Distance and Equalizing Ring: Sufficient air insulation distance must be maintained around the high-voltage divider (refer to GB/T 16927). The top equalizing ring must never be removed! It controls the electric field distribution; removing it greatly increases the risk of surface flashover.
3. Coaxial Cable Impedance Matching: The length of the coaxial cable connecting the low-voltage arm and the measuring instruments cannot be arbitrarily changed, and the termination must be connected to a matching impedance (e.g., 50Ω). If the cable is cut short or no matching resistor is connected, severe reflections and oscillations will occur when measuring impulse waveforms.
4. Anti-Flashover Cleaning: In outdoor or dusty environments, dust easily accumulates on the surface of the insulating cylinder. Before applying high voltage, the surface of the insulating cylinder must be wiped clean with anhydrous ethanol to prevent flashover.
How do I perform maintenance to extend the product's lifespan?
1. Insulation Medium Inspection: For oil-immersed voltage dividers, regularly observe the oil level gauge and replenish with the same type of transformer oil if insufficient oil is found. For SF6 gas-insulated transformers, regularly check the gas pressure and leakage rate with a leak detector.
2. Moisture and Condensation Prevention: When not in use for extended periods, store in a dry, well-ventilated place. During the rainy season in southern regions, it is best to dry the surface with a hot air blower before use, or run the transformer at low voltage for a period of time to "bake" away moisture.
Our address
Baoding Cloud Center, Hebei, China
Phone Number/whatsapp
+86 13483219412
Salesm@dualcanopy.com

FAQ
1. Q: Should I choose a resistor voltage divider or a capacitor voltage divider?
A: It depends on what you are measuring. For DC and low-frequency AC, choose a resistor voltage divider; for high-voltage AC (power frequency) requiring extremely high accuracy and no heat generation, choose a capacitor voltage divider (usually used in conjunction with a high-voltage bridge); for lightning/switching impulse measurements, a parallel RC voltage divider must be chosen (balancing response speed and steady-state accuracy).
2. Q: My voltage divider is rated at 100kV. Can I operate it at 100kV for an extended period?
A: It is not recommended. 100kV is usually the "rated maximum voltage" or "short-time withstand voltage." If you are continuously operating the withstand voltage for a long time (e.g., more than 1 hour), it is recommended to control the operating voltage at around 80% of the rated voltage (i.e., 80kV) to allow sufficient insulation margin and extend equipment life.
3. Q: When measuring impulse voltage, why does the waveform drop too quickly at the end (short waveform duration)?
A: It's highly likely that the matching resistor on the low-voltage arm or the oscilloscope's input impedance setting is incorrect, causing the discharge time constant to decrease. Please check if the 50Ω/75Ω matching resistor at the coaxial cable termination is connected correctly, and whether the oscilloscope channel impedance setting matches the requirements of the low-voltage arm of the voltage divider.