What are the requirements for the bushing in oil immersed transformer series?

Jul 25, 2025

Leave a message

Olivia Williams
Olivia Williams
Olivia is a quality control specialist at Shuangguan Electric. She has been rigorously checking the quality of electrical products and projects since 2018 to guarantee the safety and reliability of power infrastructure.

Hey there! As a supplier of oil immersed transformer series, I've been getting a lot of questions lately about the requirements for bushings in these transformers. So, I thought I'd share some insights on this topic.

First off, let's understand what bushings are and why they're so important in oil immersed transformers. Bushings are basically insulators that allow electrical conductors to pass through the tank of the transformer while maintaining electrical insulation. They play a crucial role in ensuring the safe and efficient operation of the transformer.

Electrical Requirements

One of the primary requirements for bushings in oil immersed transformers is high - voltage insulation. These transformers often operate at very high voltages, and the bushings need to be able to withstand these voltages without breaking down. For example, in large - scale power distribution systems, the transformers might operate at voltages up to hundreds of kilovolts. The bushings must have excellent dielectric properties to prevent electrical arcing between the conductor and the transformer tank.

The bushings also need to have low dielectric losses. High dielectric losses can lead to overheating, which not only reduces the efficiency of the transformer but can also cause damage to the bushing itself over time. To achieve low dielectric losses, high - quality insulating materials are used in the manufacturing of the bushings.

Another important electrical requirement is the ability to carry the rated current without excessive heating. The bushing should be designed to handle the maximum current that the transformer is expected to carry. If the bushing can't handle the current, it can lead to a rise in temperature, which can degrade the insulation and eventually cause a failure.

Mechanical Requirements

Mechanically, bushings need to be strong enough to withstand the physical stresses within the transformer. They are subjected to vibrations, thermal expansion and contraction, and sometimes even external impacts. For instance, during transportation or installation, the transformer might experience some jolts, and the bushings should be able to endure these without getting damaged.

The bushings also need to be properly sealed to prevent the leakage of the insulating oil from the transformer. A leaky bushing can not only lead to a loss of the insulating properties of the oil but can also pose a safety hazard. So, a good sealing mechanism is essential to maintain the integrity of the transformer's oil - filled environment.

Thermal Requirements

Thermal management is a key aspect of bushing performance. The bushing should be able to dissipate the heat generated during normal operation effectively. As mentioned earlier, excessive heat can damage the insulation, so the design of the bushing should allow for efficient heat transfer.

Nx3 Oil-immersed Transformer suppliersNx2 Oil-immersed Transformer factory

In some cases, special cooling features might be incorporated into the bushing design. For example, some bushings have fins or other heat - dissipating structures to increase the surface area for better heat dissipation.

Compatibility Requirements

The bushing must be compatible with the insulating oil used in the transformer. Different types of insulating oils have different chemical properties, and the bushing material should not react with the oil. If there is a chemical reaction between the bushing and the oil, it can lead to the degradation of both the bushing and the oil, reducing the overall performance and lifespan of the transformer.

Types of Bushings in Oil Immersed Transformers

There are different types of bushings used in oil immersed transformers, such as oil - filled bushings, resin - impregnated paper (RIP) bushings, and capacitor - graded bushings. Each type has its own set of advantages and is suitable for different applications.

Oil - filled bushings are relatively simple in design and are often used in medium - voltage transformers. They use oil as the insulating medium and are known for their good electrical insulation properties.

Resin - impregnated paper bushings are more commonly used in high - voltage applications. The resin - impregnated paper provides excellent insulation and mechanical strength.

Capacitor - graded bushings are designed to distribute the electrical stress more evenly along the length of the bushing. They are often used in very high - voltage transformers where precise control of the electrical field is required.

Our Product Offerings

At our company, we offer a wide range of Oil Immersed Transformer with high - quality bushings that meet all the above requirements. Our Nx3 Oil - immersed Transformer and Nx2 Oil - immersed Transformer are designed with state - of the - art bushings that ensure reliable and efficient operation.

If you're in the market for oil immersed transformers and are concerned about the quality of the bushings, don't hesitate to reach out. We can provide you with detailed information about our products and how they meet the specific requirements for your application. Whether you need a transformer for a small - scale industrial facility or a large - scale power grid, we've got you covered.

Conclusion

In conclusion, the requirements for bushings in oil immersed transformers are quite complex and involve multiple aspects, including electrical, mechanical, thermal, and compatibility factors. Choosing the right bushing is crucial for the safe and efficient operation of the transformer. If you have any questions or are interested in our oil immersed transformer series, feel free to contact us for a procurement discussion. We're here to help you find the best solution for your needs.

References

  • IEEE Standard C57.19.00 - Standard Performance Characteristics and Test Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers
  • IEC 60137 - Bushings for alternating voltages above 1000 V