Can a Partial Discharge Inspection Instrument be used for GIS partial discharge inspection?

Oct 31, 2025

Leave a message

James Brown
James Brown
James is a senior researcher in the company. He has been dedicated to developing advanced electrical technologies at Shuangguan Electric since 2018, aiming to enhance the efficiency of power infrastructure construction.

In the realm of electrical power systems, Gas - Insulated Switchgear (GIS) plays a pivotal role. GIS is widely used in power substations due to its compact design, high reliability, and long service life. However, like any electrical equipment, GIS is susceptible to partial discharge (PD), which can be an early indicator of insulation degradation and potential failures. As a supplier of Partial Discharge Inspection Instruments, I am often asked whether our instruments can be used for GIS partial discharge inspection. In this blog, I will delve into this question and provide a comprehensive answer.

Understanding Partial Discharge in GIS

Partial discharge is a localized electrical discharge that occurs within the insulation system of electrical equipment. In GIS, PD can be caused by various factors, such as manufacturing defects, contamination, mechanical stress, and aging of the insulation material. If left undetected, PD can gradually erode the insulation, leading to reduced insulation performance and eventually, complete insulation breakdown. This can result in costly power outages, equipment damage, and safety hazards.

The Importance of GIS Partial Discharge Inspection

Regular partial discharge inspection of GIS is crucial for ensuring the safe and reliable operation of power systems. By detecting PD at an early stage, maintenance personnel can take proactive measures to address the underlying issues, such as repairing or replacing faulty components, before a major failure occurs. This not only helps to prevent unplanned outages but also extends the service life of the GIS equipment, reducing overall maintenance costs.

Can a Partial Discharge Inspection Instrument be used for GIS Partial Discharge Inspection?

The answer is yes. Our Partial Discharge Inspection Instruments are designed to detect and analyze partial discharges in a wide range of electrical equipment, including GIS. These instruments utilize advanced technologies, such as ultra - high - frequency (UHF), acoustic emission (AE), and electromagnetic interference (EMI) detection, to accurately identify and locate PD sources within the GIS.

Ultra - High - Frequency (UHF) Detection

UHF detection is one of the most widely used methods for GIS partial discharge inspection. When a partial discharge occurs in GIS, it generates high - frequency electromagnetic waves in the UHF range (300 MHz - 3 GHz). Our Partial Discharge Inspection Instruments are equipped with UHF sensors that can detect these electromagnetic waves. The sensors are typically installed on the GIS enclosure or through dedicated UHF ports. Once the UHF signals are detected, the instrument analyzes the characteristics of the signals, such as amplitude, frequency, and phase, to determine the location and severity of the partial discharge.

Acoustic Emission (AE) Detection

Acoustic emission detection is another effective method for GIS partial discharge inspection. When a partial discharge occurs, it generates mechanical stress waves in the insulation material, which propagate through the GIS structure as acoustic waves. Our instruments are fitted with acoustic sensors that can detect these acoustic waves. By analyzing the acoustic signals, we can identify the presence and location of partial discharges. AE detection is particularly useful for detecting PD in areas where UHF detection may be limited, such as inside solid - insulated components.

Electromagnetic Interference (EMI) Detection

EMI detection is also employed in our Partial Discharge Inspection Instruments. Partial discharges generate electromagnetic interference in the radio - frequency range. The instrument can detect these EMI signals using specialized antennas. By analyzing the EMI signals, we can obtain information about the partial discharge activity in the GIS.

Advantages of Using Our Partial Discharge Inspection Instruments for GIS

There are several advantages to using our Partial Discharge Inspection Instruments for GIS partial discharge inspection:

High Sensitivity

Our instruments are highly sensitive and can detect even the smallest partial discharges in GIS. This allows for early detection of insulation problems, enabling timely maintenance and preventing major failures.

Accurate Location

The advanced signal processing algorithms in our instruments can accurately locate the partial discharge sources within the GIS. This helps maintenance personnel to quickly identify the faulty components and take appropriate corrective actions.

Comprehensive Analysis

Our instruments provide comprehensive analysis of partial discharge data. They can display various parameters, such as PD magnitude, repetition rate, and phase distribution, which can be used to assess the severity of the PD and the condition of the GIS insulation.

Portable and Easy to Use

Our Partial Discharge Inspection Instruments are portable and easy to use. They can be easily transported to the GIS site and set up for inspection. The user - friendly interface allows operators to quickly and efficiently perform inspections, even with minimal training.

Related Products

In addition to our Partial Discharge Inspection Instruments, we also offer other related products that can be used in conjunction with GIS inspection. For example, the Single - phase Relay Protection Test Instrument can be used to test the relay protection systems in the GIS. This ensures that the protection systems are functioning properly and can quickly isolate faulty sections in case of a fault.

The YDQ Series Inflatable Test Transformer AC/DC is another useful product. It can be used to perform high - voltage tests on the GIS insulation to verify its integrity.

Our Partial Discharge Comprehensive Analyzer provides in - depth analysis of partial discharge data, helping to accurately diagnose insulation problems in GIS.

Conclusion

In conclusion, our Partial Discharge Inspection Instruments can be effectively used for GIS partial discharge inspection. With their advanced detection technologies, high sensitivity, accurate location capabilities, and comprehensive analysis functions, these instruments are essential tools for ensuring the safe and reliable operation of GIS in power systems. If you are in need of a reliable solution for GIS partial discharge inspection, our products are the ideal choice.

We are committed to providing high - quality products and excellent customer service. If you are interested in our Partial Discharge Inspection Instruments or other related products, please feel free to contact us for more information and to discuss your specific requirements. We look forward to the opportunity to work with you on your GIS inspection projects.

Single-phase Relay Protection Test Instrument high qualityPartial Discharge Comprehensive Analyzer

References

  1. IEEE Std C37.63™ - 2018, IEEE Guide for Diagnostic Field Testing of SF6 - Insulated Substations and Gas - Insulated Transmission Lines
  2. IEC 60270:2000, High - voltage test techniques - Partial discharge measurements
  3. Eriksson, L., & Larsson, A. (2004). Partial discharge detection in gas - insulated switchgear using UHF sensors. IEEE Transactions on Dielectrics and Electrical Insulation, 11(6), 819 - 826.