Three-Phase Power Quality Tester, Harmonic Analysis

Three-Phase Power Quality Tester, Harmonic Analysis
Details:
Products Description Three-Phase Power Quality Tester, Harmonic Analysis & Electrical Parameter Detection Instrument, Industrial-Grade Precision Measurement Comprehensive analysis and diagnosis all the voltage, current, power, electrical energy, harmonic, phase and other electric parameters....
Send Inquiry
Description
Send Inquiry

Dual Canopy Mechanic Electrical Engineering Co., Ltd. is one of the leading manufacturers and suppliers of three-phase power quality tester, harmonic analysis in China. Please feel free to wholesale discount products for sale here and get quotation from our factory. Customized orders are welcome.

 

Products Description

 

product-750-750

Three-Phase Power Quality Tester, Harmonic Analysis & Electrical Parameter Detection Instrument, Industrial-Grade Precision Measurement

Comprehensive analysis and diagnosis all the voltage, current, power, electrical energy, harmonic, phase and other electric parameters.

Many kinds of current sensors provide a choice to cope with variety of measurement site.

4 channel current and 4 channel voltage measurement, simultaneously capturing and recording electric parameters and waveform, to provide with all the power quality information for working.

 

Technology Specifications

 

Host Model

Power Quality Analyzer

Power Supply

Rechargeable lithium battery 9.6V,4500mAH, external charger; working current about 490mA, battery can continuous working 8 hours

Battery Level Indicator

Battery symbol 5 grid Display power, when the battery level is low, automatically shut down after 1 minute indication

Display Mode

LCD colorful screen, 640dotsX480dots, 5.6 inches, display area:116mmX88mm

Current Test

Clamp current sensor: 008B; 040B; 068B; 300F (optional)

Voltage Test

Line voltage: 1.0V~2000V; Phase voltage: 1.0V~1000V

Electricity Energy Parameter

W, VA, var, PF, DPF, cosφ, tanφ, Wh, Varh, Vah

Channel

4 channels voltage, 4 channels current

Three-Phase Unbalance

Yes

Frequency

40Hz~70Hz

Start Current Mode

Yes, 100 seconds

Harmonic Wave

Yes, 0~50 times

Peak Value

Yes

Total Harmonic Distortion

Yes, 0~50 times, each phase

Phasor Diagram Display

automatic

Expert Mode

Yes

Screenshot Capacity

60PCS

Transient Record Groups

150groups

Menu Language

Chinese, English

Voltage Flicker

Yes

Communication Interface

USB

Record

300 days (record 20 parameters simultaneously, every second record 1 point)

Min/Max Recorded Value

Yes, the max min value can be measured for a certain time

Alarm

40 different types of parameter to selection, 12800 group alarm logs

Automatic Shut Down

In the alarm/ trend graph recording/ transient capture mode (waiting or in progress), the instrument does not automatically shut down

 

In other test modes, Automatic shutdown after starting up 15 minutes without any operation, automatically shutdown after 1 minute prompting

Backlight Function

Yes, suitable for dark places and nighttime use

Meter Size

240mmX170mmX68 mm

Instrument Weight

Total weight: about 9.2kg (include all accessories)

Input Impedance

Test voltage input impedance: 1MΩ

Suitable Safety Standard

IEC-61010 CAT III 1000V / CAT IV 600V, IEC-61010-031, IEC-61326, Pollution Degree 2

Accessories

Host: 1PCS; Instrument bag: 1pcs; Pen probe test lines: 5PCS (each 1PCS of yellow, green, red, blue, black); Alligator clip: 5PCS; Charger 1PCS; 2G Memory card: 1PCS. Clamp current sensor: (optional)(300F Current clamp with battery)

 

 

 

Current Sensor Characteristics (Optional)

 

Current sensor model

Current Clamp

Current True RMS

Current True RMS Max Error

Phase Angle φ Max Error

CT Size: Ф8mm

product-259-113

10mA~99mA

100mA~10.0A

±(1% rdg+ 3dgt)

±(1%rdg + 3dgt)

±(1.5°),Arms≥20mA

±(1°)

CT Size: Ф40mm

product-544-282

0.10A~0.99A

1.00A~100A

±(1%rdg + 3dgt)

±(1% rdg+ 3dgt)

±(1.5°)

±(1°)

CT Size: Ф68mm

product-575-341

1.0A~9.9A

10.0A~1000A

±(2 % rdg+ 3dgt)

±(2 %rdg + 3dgt)

±(3°)

±(2°)

CT: Ф300mm

product-111-74

10A~99A

100A~6000A

±(1 %rdg + 3dgt)

±(1 %rdg + 3dgt)

±(3°)

±(2°)

 

Instrument Accuracy

 

Measurement specification

Range

Display resolution

Max Error

Frequency

40Hz~70Hz

0.01Hz

±(0.03)Hz

Phase Voltage True RMS

1.0V~1000V

Min resolution0.1V

±(0.5%rdg+5dgt)

Line Voltage True RMS

1.0V~2000V

Min resolution0.1V

±(0.5%rdg+5dgt)

DC Voltage

1.0V~1000V

Min resolution0.1V

±(1.0%rdg+5dgt)

Current True RMS

10mA~6000A

Min resolution0.1mA

±(0.5%rdg+2dgt)

Phase Voltage Peak

1.0V~1414V

Min resolution0.1V

±(1.0%rdg+5dgt)

Line Voltage Peak

1.0V~2828V

Min resolution0.1V

±(1.0%rdg+5dgt)

Current Peak

10mA~6000A

Min resolution0.1mA

±(1.0%rdg+5dgt)

Peak Factor

1.00~3.99

0.01

±(1%rdg+2dgt)

 

4.00~9.99

0.01

±(5%rdg+2dgt)

Active Power

0.000W~9999.9kW

Min resolution 0.001W

±(1%rdg+3dgt); Cosφ≥0.8

 

   

±(1.5%rdg+10dgt); 0.2≤Cosφ<0.8

Reactive power

Inductive& Capacitive

0.000VAR~9999.9kVAR

Min resolution 0.001VAR

±(1%rdg+3dgt); Sinφ≥0.5

 

   

±(1.5%rdg+10dgt); 0.2≤Sinφ<0.5

Apparent Power

0.000VA~9999.9kVA

Min resolution 0.001VA

± (1%rdg+3dgt %)

Power Factor

-1.000~1.000

0.001

±(1.5%rdg+3dgt); Cosφ≥0.5

 

   

±(1.5%rdg+10dgt); 0.2≤Cosφ<0.5

Active Energy

0.000Wh~9999.9MWh

Min resolution 0.001Wh

±(1%rdg+3dgt); Cosφ≥0.8

 

   

±(1.5%rdg+10dgt); 0.2≤Cosφ<0.8

Reactive Energy

Inductive& Capacitive

0.000VARh~9999.9MVARh

Min resolution 0.001VARh

±(1%rdg+3dgt); Sinφ≥0.5

 

   

±(1.5%rdg+10dgt); 0.2≤Sinφ<0.5

Apparent Energy

0.000VAh~9999.9MVAh

Min resolution 0.001VAh

±(1%rdg+3dgt)

Phase Angle

-179°~180°

1°

±(2°)

Tanφ(VA≥50VA)

-32.768~32.768

Min resolution 0.001

±(1%rdg+5dgt)

Displacement Power Factor (DPF)

-1.000~1.000

0.001

±(1%rdg+5dgt)

Harmonic Ratio(Vrms>50V)

0.0 %~99.9 %

0.1 %

±(1%rdg+5dgt)

Harmonic Angle (Vrms >50V)

-179°~180°

1°

±(3°)harmonic1~25

 

   

±(10°)harmonic26~50

Total Harmonic Rate

(DF or THD-F)≤50

0.0 %~99.9 %

0.1 %

±(1%rdg+5dgt)

Distortion Factor

(DF or THD-R)≤50

0.0 %~99.9 %

0.1 %

±(1%rdg+10dgt)

Transformer K Factor

1.00~99.99

0.01

±(5 %)

Three-phase Unbalance

0.0%~100 %

0.1 %

±(1 %)

 

 