High Accuracy Transformer Load No-load And Capacity

High Accuracy Transformer Load No-load And Capacity
Details:
Overview The High Accuracy Transformer Load No-load and Capacity transformer capacity loss tester is a new instrument developed and designed by our company's R&D personnel specifically for the problem of bad power users evading basic electricity fees and privately increasing capacity. It...
Send Inquiry
Description
Send Inquiry

Dual Canopy Mechanic Electrical Engineering Co., Ltd. is one of the leading manufacturers and suppliers of high accuracy transformer load no-load and capacity in China. Please feel free to wholesale discount products for sale here and get quotation from our factory. Customized orders are welcome.

 

 

What are high-accuracy transformer load, no-load, and capacity tests?

 

 

product-750-750

The High-Accuracy Transformer Capacity & Loss Analyzer is a precision diagnostic platform developed by our engineering team. Originally conceived to assist utilities with revenue protection and asset verification-specifically identifying unauthorized capacity upgrades and tariff evasion-it has evolved into a comprehensive instrument for measuring transformer capacity and key characteristic parameters.

The system features a large-format color LCD with a full Chinese-language graphical interface, offering intuitive menu-driven operation and a user-friendly human-machine interface. An integrated high-efficiency rechargeable battery enables fully autonomous field operation; a single full charge supports continuous measurement of more than 100 transformer sets without any external power source. Additionally, the instrument incorporates a built-in three-phase precision 50 Hz sinusoidal AC test supply, eliminating the need for external three-phase power, voltage regulators, or current boosters during capacity and load-loss testing. This all-in-one design significantly streamlines workflow complexity and improves overall field productivity.

What are the accuracy and range of the High Accuracy Transformer Load No-load And Capacity?

product-750-750

1. Built-in power supply output range

          Voltage: 0~10V

          Current: 0~10A

2. Characteristic test power supply input range

          Voltage: 0~750V

          Current: 0~100A

3. Test accuracy

           Voltage, current: ±0.2%

           Power: ±0.5% (CosΦ>0.1), ±1.0% (0.02

4. Insulation

           ⑴. Capacity test, voltage, current input point insulation resistance to the housing ≥100MΩ

           ⑵. Charging power input to the housing withstands 2KV (effective value) of power frequency, test time 1 minute

 

What should I do if the measurement range is insufficient?

 

The voltage and current ranges can be flexibly extended using external potential transformers (PT) and current transformers (CT) to broaden test coverage; additionally, internal protection circuitry eliminates the risk of instrument damage due to incorrect range selection.

 

What is the principle of the no-load test?

 

 

To determine no-load current and no-load losses, one winding of the transformer-typically the low-voltage side-is energized at rated voltage and frequency while all other windings remain open-circuited. Accurate measurements are only achievable when the applied voltage reaches at least 70% of the rated value.

 

In what types of scenarios are high-accuracy transformer load, no-load, and capacity testers typically used?

 

Factory & Commissioning Quality Assurance

Verify that no-load loss, load loss, and impedance voltage conform to both applicable standards and nameplate ratings, thereby supporting factory acceptance testing (FAT) and pre-energization handover procedures.

Condition Assessment & Trend Analysis

Compare current loss and impedance measurements against historical baseline data to identify incipient winding deformation, core degradation, or insulation aging trends-facilitating evidence-based condition assessment and maintenance planning.

 

What are the interfaces for High Accuracy Transformer Load No-load And Capacity?

 

It is equipped with dedicated terminals for characteristic testing and a data upload communication interface; combined with capacity test ports, a printer, an LCD, and a keypad, it forms a complete measurement and output unit.
The chassis must be reliably grounded. Insulation requirements: resistance between any input terminal and the chassis must be ≥100 MΩ; the charging power input must withstand a 2 kV (RMS) power-frequency withstand voltage test against the chassis for one minute.

 

 

How can I get a product quote?

 

Our address

Baoding Cloud Center, Hebei, China

Phone Number/whatsapp

+8613603329412

E-mail

dylan@dualcanopy.com

modular-1
 

FAQ

 

 

Q: Can the records be printed?
A: Current test results can be output directly via the built-in printer, facilitating the on-site issuance of hard-copy records.
Q: How is data exported?
A: Data is stored within the instrument and can be uploaded to a computer via a data cable; using the communication software, select the COM port and choose "Upload Data" to import the data into the database.

Q: What about grounding and safety?
A: The instrument casing must be reliably grounded. Insulation requirements: resistance between input terminals and the casing must be ≥100 MΩ; the charging power input must withstand a 2 kV (RMS) power-frequency withstand voltage test against the casing for 1 minute.

 

Hot Tags: high accuracy transformer load no-load and capacity, China high accuracy transformer load no-load and capacity manufacturers, suppliers, factory, Transformer capacity And no load test kit, Portable Transformer Capacity Characteristic Tester

Send Inquiry