Dual Canopy Mechanic Electrical Engineering Co., Ltd. is one of the leading manufacturers and suppliers of CT And PT Testing in China. Please feel free to wholesale discount products for sale here and get quotation from our factory. Customized orders are welcome.
What is CT And PT Testing?

The CT And PT Testing is a versatile instrument for evaluating current transformers (CTs) and voltage transformers (PTs/VTs) in both substation and laboratory settings. It runs the full range of essential tests and captures the data needed for a thorough assessment.
For CTs, it checks excitation characteristics, turns ratio, polarity, and secondary circuit properties. For PTs-depending on how the unit is configured-it verifies turns ratio, phase relationship, and measurement errors. These capabilities let technicians confirm that transformers are wired and installed correctly, that metering and protection systems will perform to spec, and that there are no looming saturation issues or hidden winding and insulation problems. The results feed directly into commissioning acceptance, routine preventive maintenance schedules, and fault-finding investigations.
What is Main technical parameters?
|
Test purpose |
Protection CT, Protection PT |
|
|
Output |
0~180Vrms, 12Arms, 36A (peak) |
|
|
CT ratio measurement |
Range |
1~50000 |
|
Accuracy |
±0.1% |
|
|
PT ratio measurement |
Range |
1~50000 |
|
Accuracy |
±0.1% |
|
|
Phase measurement |
Accuracy |
±2min |
|
Resolution |
0.5min |
|
|
Secondary winding resistance measurement |
Range |
0~300Ω |
|
Accuracy |
0.2%±2mΩ |
|
|
AC load measurement |
Range |
0~1000VA |
|
Accuracy |
0.2%±0.02VA |
|
|
Input power supply voltage |
AC220V±10%,50Hz |
|
|
Working environment |
Temperature: -10οC~50οC, Humidity: ≤90% |
|
|
Dimensions, weight |
Dimensions: 340mm x 220mm x 330mm Weight: < 9kg |
|
What are the typical applications?
Current Transformers (CTs): Protection CTs, metering CTs, bushing CTs, GIS built-in CTs, etc.
Voltage Transformers (PTs/VTs): Electromagnetic PTs, CVTs (secondary side test items depend on configuration)
Secondary Circuits: Circuit continuity, polarity verification, terminal marking verification (according to the test plan)
What are the main features?
1. CT Excitation Characteristic Test and Curve Generation
Automatically acquires excitation curves.
Extracts key points: e.g., knee point voltage, magnetizing current, saturation trend, etc. (output items vary depending on the model algorithm)
2. CT Ratio, Polarity, and Phase Relationship Verification
Supports CT ratio testing and polarity determination.
Can be used for quick on-site verification of terminal markings and wiring directions, reducing the risk of incorrect protection/metering connections.
3. Secondary Circuit and Burden Related Tests (by configuration)
Supports circuit resistance, load assessment, admittance/impedance, etc. (specific items vary depending on the model).
Helps confirm secondary circuit voltage drop and load matching, reducing sources of error.
4. PT/VT Ratio and Error Assessment (by configuration)
Supports PT ratio, phase, and error testing, suitable for on-site verification and laboratory testing needs.
FAQ
Q1: What causes unstable excitation curves or high noise?
A: Common causes include poor wiring contact, terminal oxidation, interference, or improper voltage boosting rhythm. It is recommended to check the wiring and fixture fixation and retest.
Q2: Does it support data storage and report export?
A: Yes, export methods and report formats are configured according to the model (USB/software/print, etc.).
Q3: Can it be used for handover and acceptance reports?
A: Yes. It is recommended to also record the transformer nameplate parameters, accuracy class, rated load, tap information, etc., for a more complete report.
Hot Tags: CT And PT Testing, China CT And PT Testing manufacturers, suppliers, factory, ct pt analyzers, voltage transformer analyzer ct pt, Volt Ampere Characteristic Tester Current Transformer Test Machine